ASAP Defense Parts is a streamlined procurement platform for those seeking in-demand NSN parts, military and defense parts, aerospace parts, and other comparable items. We appreciate your interest in part number CTR015, a General Dynamics Satcom product that is listed alongside the description “Transformer Power” and the NSN 6120014699388. You are always welcome to request quotes for part number CTR015 by filling out and submitting the RFQ form below, and we promise swift responses with customized solutions provided in 15 minutes or less from the review of a completed form.
Note : We Will Not Share Your Information With Any Third Parties.
For your convenience, we list items like General Dynamics Satcom part number CTR015 with all relevant designations. For example, while part number CTR015 belongs to NSN 6120-01-469-9388, it is also categorized under FSC 6120 Transformers Distribution and Power Station, a commodity classification designation that organizes similar products together. Moreover, in contrast to other websites that often require one to choose between quality, pricing, and timely fulfillment, we routinely utilize our market expertise and purchasing power to present optimal solutions that cater to the unique specifications of each customer. With all of this in mind, begin the procurement process for part number CTR015 from CAGE Code 1GD22 on our website, and see why so many customers steadily depend on us for their needs.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
6120-01-469-9388 Item PartTypeName: TRANSFORMER,POWER | 6120 | 014699388 | N | A | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
A | A | 0 | ||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
CTR015 | 5 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
ABTB | Mounting Hole Diameter | 0.250 INCHES NOMINAL SINGLE GROUP |
CWJS | Winding Operating Voltage | 117.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
CBBL | Features Provided | COLOR CODED LEAD AND PROTECTIVE COVER AND SPECIAL MARKING |
ADAU | Body Height | 1.900 INCHES NOMINAL |
ACZB | Frequency Rating | 50.0 HERTZ NOMINAL SINGLE COMPONENT OR 60.0 HERTZ NOMINAL SINGLE COMPONENT |
CRBZ | Winding Operating Current | 0.6 AMPERES AC NOMINAL SINGLE COMPONENT SINGLE SECONDARY |
TTQY | Terminal Type And Quantity | 4 WIRE LEAD |
CRBZ | Winding Operating Current | 0.7 AMPERES AC MINIMUM SINGLE COMPONENT SINGLE PRIMARY AND 1.4 AMPERES AC MAXIMUM SINGLE COMPONENT SINGLE PRIMARY |
ACZF | Maximum Transformer Power Rating | 150.0 VOLT-AMPERE SINGLE COMPONENT |
AXGY | Mounting Method | UNTHREADED HOLE SINGLE GROUP |
FEAT | Special Features | SUPPLY VOLTAGE RANGE IS PLUS OR MINUS 10 PERCENT; PRIMARIES ARE INSIDE SLEEVE AND MUST BE CONNECTED TOGETHER IN SERIES OR PARALLEL; PRIMARY LEAD WIRES ARE MAGNET WIRE SELF-LEADS, 24 GAUGE, 8.000 IN. LENGTH NOMINAL; SECONDARY LEAD WIRES ARE MULTI-STRANDED, 22 GAUGE, 8.000 IN. LENGTH NOMINAL; CORE NO. 900140, NO-LOAD LOSS EQUALS 0.9 WATT , NO-LOAD AMPERAGE EQUALS 8.7 MILLIAMPS; UL RECOGNIZED TO UL 1411 AND CSA CERTIFIED TO CSA C22.2, NO. 66 |
ADAR | Body Outside Diameter | 3.900 INCHES NOMINAL |
MRC | Decoded Requirement | Clear Text Reply |
AEHZ | Maximum Operating Temp | 65.0 DEG CELSIUS |
CWJS | Winding Operating Voltage | 117.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE SECONDARY |
AARG | Reliability Indicator | NOT ESTABLISHED |
AKNA | Inclosure Type | FULLY INCLOSED |